Francis Turbine/ Turgo Turbine/ Pelton Turbine/ Kaplan Turbine/ Tubular Turbine Generator Unit

Product Details
Customization: Available
Transport Package: Wood Box
Specification: CE / IEC / ISO / A
Diamond Member Since 2011

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
28
Year of Establishment
1998-07-20
  • Francis Turbine/ Turgo Turbine/ Pelton Turbine/ Kaplan Turbine/ Tubular Turbine Generator Unit
Find Similar Products

Basic Info.

Trademark
FUCHUN
Origin
China
Production Capacity
5000

Product Description

Francis turbine
Francis turbine is a kind of turbine suit to water head 20-300meters and with certain suitable flow.
It could be divided into vertical and horizontal arrangement. Francis turbine have the advantage of high efficiency, small size and reliable structure.

Horizontal Francis turbine unit, with horizontal shaft, could be 2 or three supports. Which is normally one stair arrangement. Simple structure, easier operation and maintainence.
Vertical Francis turbine unit, with vertical shaft, metal spiral case or concrete spiral case. With adjustable guide vane, and stay ring etc parts, are suit to runner diameter bigger than 1000mm. Our engineer will select the most suitable Francis turbine for your hydro power project.

Francis runner

Francis runner material could be stainless steel or carbon steel. The upper crown, lower ring, and blades are partial casted, polished, and then welded together. After heat treatment and fine polished, the factory tests including static and dynamic balance test, UT test, and dimension measurement. Our runners are guaranteed 100% all parameters meet the requirement, and related regulation.

Pelton Turbine

Pelton turbine suit to water head 100 to 1000 meters and with certain small flow. It could vertical and horizontal arrangement, nozzle numbers from one to six. Pelton turbine with feature of wide flow high efficiency region. It could start turbine with 10% of rated flow. Pelton turbine with one or two nozzles usually adopt horizontal arrangement, but multiple nozzle Pelton turbine adopts vertical arrangement. Pelton turbine units are wildly used in mountain area all over the world, and well known by its simple structure, less investment, high efficiency, and reliable long service life.

Pelton runner manufacture workmanship has been improved sharply in recent years. The runner could be wholly casted or forged stainless steel and then be shaped and polished by digital control machine tool. Pelton runner has been manufactured by us all this high strength, higher efficiency, and longer service life. The factory tests including static and dynamic balance test, UT test, and dimension measurement.

Kaplan turbine

Kaplan turbine is a kind of turbine suit to low water head 2-20 meters, and with certain big flow, normally divided into fixed blades and adjustable blades turbine. Main components including: Runner, draft cone, water chamber, guide vane, bearing, and main shaft. The spiral case could be steel or concrete. The runner diameter we can manufacture is from 60cm to 4meters, with rated output 50Kw to 20Mw.
Turbine units normally be vertical shaft arrangement. Generator equipped with same or different shaft, with Anyway, they will share the same rotating speed. If specially specially required, a speed increase gear could be equipped between turbine and generator in order to smaller the generator size.

Kaplan Runner
Kaplan runner with 3 to 6 blades, fixed blades runner, blades are casted and then welded on the runner hub, and bolts connection with draft cone. Regarding the adjustable blades runner, the hub is designed to be hollow, and a control rod is designed in the shaft middle to change blades angle in order to suit different flow.
Runner material: Stainless steel, or other specified by the client
Kaplan runner has been manufactured by us all this high strength, higher efficiency, and longer service life. The factory tests including static and dynamic balance test, UT test, and dimension measurement.
Reference List of Some Export Projects
No. Country and Power Station Exported to Technical Parameters Type Qty Date of contract
1 Latin America

1 2013,12
2 Latin America Rated head:305m
Rated flow:0.385m³/s
Frequency:60Hz
Outgoing line voltage:480V
CJA475-W-80/2×6.5
SFW1000-8/1180
1 2013.06
3 South Asia Type:HL855a
Runner diameter:1750mm
27Mw spare runners  1 2013.06
4 Europe  Rated head:73.8m
Rated flow:0.1325m³/s
Frequency:50Hz
Outgoing line voltage:400V
CJA237-W-55/1×7 1 2013.03
5 Europe Rated head:203m
Rated flow:0.312m³/s
Frequency:50Hz
Outgoing line voltage:400V
CJA237-W-80/1×8.5
SFW500-8/990
1 2013.05
6 South Asia Rated head:88m
Rated flow:1.41m³/s
Frequency:50Hz
Outgoing line voltage:400V
HLA550-WJ-62
SFW1000-6/1180
1 2013.05
7 West Africa Rated head:210m
Rated flow:0.423m³/s
Frequency:50Hz
Outgoing line voltage:400V
CJA237-W-80/1×9.5
SFW700-8/1180
1 2013.05
8  
Latin America
Rated head:925m
Rated flow:0.26m³/s
Frequency:60Hz
Outgoing line voltage:4.16KV
CJC601-W-100/1×5
SFW1980-6/1430
2 2012.12
9
Southeast Asia
Rated head:4m
Rated flow:10m³/s
Frequency:60Hz
Outgoing line voltage:440V
ZD-LH-160
SF320-36/2150
1 2012.12
10
Latin America
Rated head:128m
Rated flow:0.6+0.3m³/s
Frequency:60Hz
Outgoing line voltage:440V
CJA475-W-80/2×9
SFW614-12/1180
CJA475-W-80/2×6.5
SFW302-12/990
2 2012.11
11 Europe Rated head:48.51m
Rated flow:0.351m³/s
Frequency:50Hz
Outgoing line voltage:400V
XJA-W-55B/1x8.5 1 2012.11
12 Europe Rated head:47.48m
Rated flow:0.38m³/s
Frequency:50Hz
Outgoing line voltage:400V
HL110-WJ-42 1 2012.11
13 Europe Rated head:25.44m
Rated flow:0.332m³/s
Frequency:50Hz
Outgoing line voltage:400V
HLD54-WJ-50 1 2012.11
14 Europe  Rated head:35.19m
Rated flow:0.3m³/s
Frequency:50Hz
Outgoing line voltage:400V
HLD54-WJ-50 1 2012.11
15 Europe  Rated head:37.82m
Rated flow:0.291m³/s
Frequency:50Hz
Outgoing line voltage:400V
HLD54-WJ-50 1 2012.11
16 Latin America Rated head:60m
Rated flow:1.24m³/s
Frequency:60Hz
Outgoing line voltage:440V
HLA575c-WJ-56
SFW600-8/990
2 2012.8
17 Europe Rated head:58.1m
Rated flow:0.169m³/s
Frequency:50Hz
Outgoing line voltage:400V
XJA-W-40/1×9
SFW100-8/590
1 2012.04
18 Latin America Rated head:38m
Rated flow:1.64m³/s
Frequency:60Hz
Outgoing line voltage:440V
HL220-WJ-50
SFW470-8/990
1 2012.04
19 Europe Rated head:43m
Rated flow:0.59m³/s
Frequency:50Hz
Outgoing line voltage:400V
HL110-WJ-42
HLD54-WJ-40
2 2012.03
20 South Asia Type:HL855a
Runner diameter:1750mm
27Mw spare runners  3 2011.11
21 Europe Rated head:134m
Rated flow:0.25m³/s
Frequency:50Hz
Outgoing line voltage:400V
CJA475-W-80/2×6.5
SFW250-10/850
2 2011.06
22 Europe Rated head:228m
Rated flow:0.4m³/s
Frequency:50Hz
Outgoing line voltage:400V
CJA475-W-85/1×9.5
SFW715-8/1180
3 2011.05
23 Europe Rated head:61.8m
Rated flow:0.221m³/s
Frequency:50Hz
Outgoing line voltage:400V
XJA-W-42/1×10
SFW100-8/590
1 2011.03
24 Europe  Rated head:379.7m
Rated flow:0.685m³/s
Frequency:50Hz
Outgoing line voltage:10.5KV
CJA475-W-105/2×7.5
SFW2150-8/1730
1 2010.12
25 Europe  Rated head:461.6m
Rated flow:0.786m³/s
Frequency:50Hz
Outgoing line voltage:10.5KV
CJA475-W-115/2×8
SFW3000-8/1730
1 2010.12
26 Europe Rated head:29m
Rated flow:3.2m³/s
Frequency:50Hz
Outgoing line voltage:400V
HLD41-WJ-42
HLD74-WJ-60
2 2010.12
27
Middle Asia
Rated head:36m
Rated flow:1.67m³/s
Frequency:50Hz
Outgoing line voltage:400V
HL295-LJZ-50
SF500--6/850
5 2010.12
28  
South Asia
Rated head:206m
Rated flow:0.89m³/s
Frequency:50Hz
Outgoing line voltage:6.6kV
CJA475-W-100/2×10
SFW1500-10/1430
2 2010.08
29 Southeast Asia Rated head:385m
Rated flow:11.24m³/s
Frequency:50Hz
Outgoing line voltage:13.8kV
(37.5Mw)HL69-LJ-205
SF37500-10/3600
2 2010.02
30  
East Asia
Rated head:206.8m
Rated flow:0.358m³/s
Frequency:50Hz
Outgoing line voltage:400V
CJA237-W-80/1×9
SFW570-8/990
1 2010.04
31
South Asia
Rated head:47.5m
Rated flow:2.62m³/s
Frequency:50Hz
Outgoing line voltage:6.6kV
HLA696-WJ-68
SFW1000-8/1180
3 2010.03
32 Europe Rated head:35m
Rated flow:4.25m³/s
Frequency:50Hz
HLA696-WJ-82
SFW800-12/1430
HLJF2504-WJ-56
SFW400-8/990
3 2010.01
33 Europe Rated head:265m
Rated flow:0.734m³/s
Frequency:50Hz
Outgoing line voltage:6.3kV
CJA475-W-110/2×8.5
SFW1600-10/1730
2 2009.07
34 Europe Rated head:289m
Rated flow:1.775m³/s
Nozzle No.:2
Bucket No.: 20
Runner Outer Diameter: 1600mm
RUNNER DIAMETER: 1300mm
4000KW Pelton runner and shaft spares  3 2009.06
35
Southeast Asia
Rated head:86.2m
Rated flow:22.5m³/s
Frequency:50Hz
Outgoing line voltage:10.5kV
(17Mw) HLA883-LJ-155
SF17000-12/3250
2 2008.01

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier