100kw to 50MW Hydro Turbine with Generator / Hydro Turbine Generator

Product Details
Customization: Available
Output Type: AC Three Phase
Size: Medium
Diamond Member Since 2011

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
28
Year of Establishment
1998-07-20
  • 100kw to 50MW Hydro Turbine with Generator / Hydro Turbine Generator
Find Similar Products

Basic Info.

Model NO.
HL/CJ/ZZ/GD
Type
Hydro Power
Bearing Support
Pedestal Bearing
Speed
Medium Speed
Bearing Number
2
Standard
Standard
Turbine Type
Francis / Pelton / Kaplan / Tubular / Turgo
Shaft Type
Horizontal / Vertical
Material
Stainless Steel
Transport Package
Wooden Case
Specification
CE/IEC
Trademark
FUCHUN
Origin
China
Production Capacity
500 Sets / Year.

Product Description

100KW to 50MW hydro turbine with generator / hydro turbine generator
 
Product:
Rated Power:100Kw to 50Mw
Rate Head: 2m-1200m
Frequency: 50HZ or 60HZ
Rated voltage: 380V,400V,440V,3.3KV,6.3KV,6.6KV,10.5KV,ect.
Material: stainless steel
Type: Francis, Pelton, Turgo, Kaplan, Tubular 

Description:
1.Francis 
The Francis turbine are mostly suitable for hydro power station with medium or high head. The francis turbine we supply are compact in structure,reasonable in design,convenient in operation and maintenance and excellent in efficency. They are both vertical and horizontal shaft arrangement and can be vastly selected by the hydraulic power station.
 
2.Pelton
Pelton turbine also called a free-jet turbine or Pelton wheel, a type of impulse turbine, named after L. A. Pelton who invented it in 1880. Water passes through nozzles and strikes spoon-shaped buckets or cups arranged on the periphery of a runner, which causes the runner to rotate, producing mechanical energy. The runner is fixed on a shaft, and the rotational motion of the turbine is transmitted by the shaft to a generator.
The impulse type turbines made by Fuchun are ranging from 80 to 1,000m in water head,200kW to 20MW in capacity and 0.55 to 2.3 in runner diameter. Theirs shaft arrangements are either vertical or horizontal and they may have single nozzle, twin or multi-nozzles.
100kw to 50MW Hydro Turbine with Generator / Hydro Turbine Generator

3.Kaplan
Kaplan turbine also known as axial flow Turbine is developed in 1913 by the Austrian professor Kaplan.Its invention allowed efficient power production in low-head applications that was not possible with Francis turbines.The feature of  Kaplan turbine is the water flow passes through the runner axially.
Kaplan turbines are widely used throughout the world for electrical power production. They cover the lowest head hydro sites and are especially suited for high flow conditions.

4.Tubular
The tubular turbines are the best selection for exploitation of tidal power and hydraulic power with extremely low heads and extremely large flow rates. They have large discharge,high specific and high efficiency, and need less excavation.They have been classified into Bulb, Pit, Siphon and S" types in the light of their structural types.
100kw to 50MW Hydro Turbine with Generator / Hydro Turbine Generator

Our service
Fuchun Industry Development Co., ltd Shenzhe is an experienced manufacture and engineering Company in small scale hydro power equipment ( 50Kw to 50Mw). We play the role of manufacture and EPC contractor and could supply water to wire equipments and services.
    We provide customers with the complete package, from the design and manufacture of the turbine, generator and control equipment through to installation, commissioning and ongoing repair and maintenance.
1.Water Turbine Generator Unit Design & SUPPLY
2.Hydropower equipment supply 
3.Feasibility study of hydropower project
4.Manufacture
5.Installation & Supervision
6.Commissioning and Training service
7. Hydro power plant rehabilitant

8. Hydro power plant spares supply
9.Services

100kw to 50MW Hydro Turbine with Generator / Hydro Turbine Generator

 
Reference List of Some Export Projects
No. Country and Power Station Exported to Technical Parameters Type Qty Date of contract
1 HPP2
 Guatemala
Rated head:305m
Rated flow:0.385m³/s
Frequency:60Hz
Outgoing line voltage:480V
CJA475-W-80/2×6.5
SFW1000-8/1180
1 2013.06
2  Pakistan  Type:HL855a
Runner diameter:1750mm
27Mw spare runners  1 2013.06
3 UK Rated head:73.8m
Rated flow:0.1325m³/s
Frequency:50Hz
Outgoing line voltage:400V
CJA237-W-55/1×7 1 2013.03
4 turkey Rated head:203m
Rated flow:0.312m³/s
Frequency:50Hz
Outgoing line voltage:400V
CJA237-W-80/1×8.5
SFW500-8/990
1 2013.05
5 Sri Lanka Rated head:88m
Rated flow:1.41m³/s
Frequency:50Hz
Outgoing line voltage:400V
HLA550-WJ-62
SFW1000-6/1180
1 2013.05
6 Congo Rated head:210m
Rated flow:0.423m³/s
Frequency:50Hz
Outgoing line voltage:400V
CJA237-W-80/1×9.5
SFW700-8/1180
1 2013.05
7  
Ecuador
Rated head:925m
Rated flow:0.26m³/s
Frequency:60Hz
Outgoing line voltage:4.16KV
CJC601-W-100/1×5
SFW1980-6/1430
2 2012.12
8
Philippines 
Rated head:4m
Rated flow:10m³/s
Frequency:60Hz
Outgoing line voltage:440V
ZD-LH-160
SF320-36/2150
1 2012.12
9
 Guatemala
Rated head:128m
Rated flow:0.6+0.3m³/s
Frequency:60Hz
Outgoing line voltage:440V
CJA475-W-80/2×9
SFW614-12/1180
CJA475-W-80/2×6.5
SFW302-12/990
2 2012.11
10 UK Rated head:48.51m
Rated flow:0.351m³/s
Frequency:50Hz
Outgoing line voltage:400V
XJA-W-55B/1x8.5 1 2012.11
11  UK Rated head:47.48m
Rated flow:0.38m³/s
Frequency:50Hz
Outgoing line voltage:400V
HL110-WJ-42 1 2012.11
12 UK Rated head:25.44m
Rated flow:0.332m³/s
Frequency:50Hz
Outgoing line voltage:400V
HLD54-WJ-50 1 2012.11
13 UK Rated head:35.19m
Rated flow:0.3m³/s
Frequency:50Hz
Outgoing line voltage:400V
HLD54-WJ-50 1 2012.11
14 UK Rated head:37.82m
Rated flow:0.291m³/s
Frequency:50Hz
Outgoing line voltage:400V
HLD54-WJ-50 1 2012.11
15  HPP1
 Guatemala 
Rated head:60m
Rated flow:1.24m³/s
Frequency:60Hz
Outgoing line voltage:440V
HLA575c-WJ-56
SFW600-8/990
2 2012.8
16 UK Rated head:58.1m
Rated flow:0.169m³/s
Frequency:50Hz
Outgoing line voltage:400V
XJA-W-40/1×9
SFW100-8/590
1 2012.04
17 Ecuador Rated head:38m
Rated flow:1.64m³/s
Frequency:60Hz
Outgoing line voltage:440V
HL220-WJ-50
SFW470-8/990
1 2012.04
18 Italy  Rated head:43m
Rated flow:0.59m³/s
Frequency:50Hz
Outgoing line voltage:400V
HL110-WJ-42
HLD54-WJ-40
2 2012.03
19  Pakistan  Type:HL855a
Runner diameter:1750mm
27Mw spare runners  3 2011.11
20 ITALY Rated head:134m
Rated flow:0.25m³/s
Frequency:50Hz
Outgoing line voltage:400V
CJA475-W-80/2×6.5
SFW250-10/850
2 2011.06
21 Italy Rated head:228m
Rated flow:0.4m³/s
Frequency:50Hz
Outgoing line voltage:400V
CJA475-W-85/1×9.5
SFW715-8/1180
3 2011.05
22  UK Rated head:61.8m
Rated flow:0.221m³/s
Frequency:50Hz
Outgoing line voltage:400V
XJA-W-42/1×10
SFW100-8/590
1 2011.03
23 HPP1
Albania
Rated head:379.7m
Rated flow:0.685m³/s
Frequency:50Hz
Outgoing line voltage:10.5KV
CJA475-W-105/2×7.5
SFW2150-8/1730
1 2010.12
24  HPP2
Albania
Rated head:461.6m
Rated flow:0.786m³/s
Frequency:50Hz
Outgoing line voltage:10.5KV
CJA475-W-115/2×8
SFW3000-8/1730
1 2010.12
25  Italy  Rated head:29m
Rated flow:3.2m³/s
Frequency:50Hz
Outgoing line voltage:400V
HLD41-WJ-42
HLD74-WJ-60
2 2010.12
26
Afghanistan 
Rated head:36m
Rated flow:1.67m³/s
Frequency:50Hz
Outgoing line voltage:400V
HL295-LJZ-50
SF500--6/850
5 2010.12
27  
Pakistan
Rated head:206m
Rated flow:0.89m³/s
Frequency:50Hz
Outgoing line voltage:6.6kV
CJA475-W-100/2×10
SFW1500-10/1430
2 2010.08
28  HPP1
Vietnam
Rated head:385m
Rated flow:11.24m³/s
Frequency:50Hz
Outgoing line voltage:13.8kV
HL69-LJ-205
SF37500-10/3600
2 2010.02
29  
Mozambique
Rated head:206.8m
Rated flow:0.358m³/s
Frequency:50Hz
Outgoing line voltage:400V
CJA237-W-80/1×9
SFW570-8/990
1 2010.04
30
Pakistan 
Rated head:47.5m
Rated flow:2.62m³/s
Frequency:50Hz
Outgoing line voltage:6.6kV
HLA696-WJ-68
SFW1000-8/1180
3 2010.03
31  Italy  Rated head:35m
Rated flow:4.25m³/s
Frequency:50Hz
HLA696-WJ-82
SFW800-12/1430
HLJF2504-WJ-56
SFW400-8/990
3 2010.01
32 Italy  Rated head:265m
Rated flow:0.734m³/s
Frequency:50Hz
Outgoing line voltage:6.3kV
CJA475-W-110/2×8.5
SFW1600-10/1730
2 2009.07
33 Georgia Rated head:289m
Rated flow:1.775m³/s
Nozzle No.:2
Bucket No.: 20
Runner Outer Diameter: 1600mm
RUNNER DIAMETER: 1300mm
4000KW Pelton runner change  3 2009.06
34
Vietnam
Rated head:86.2m
Rated flow:22.5m³/s
Frequency:50Hz
Outgoing line voltage:10.5kV
HLA883-LJ-155
SF17000-12/3250
2 2009.01

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier