• Small Francis Turbine / Francis Turbine for Hydro Power Plant

Small Francis Turbine / Francis Turbine for Hydro Power Plant

Output Type: AC Three Phase
Size: Medium
Type: Francis
Bearing Support: Pedestal Bearing
Speed: Medium Speed
Bearing Number: 2
Customization:
Diamond Member Since 2011

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
HL
Standard
Standard
Shaft Type
Horizontal / Vertical
Capacity
50kw~50MW
Water Head
10 to 300m
Frequency
50Hz / 60Hz
Excitation
SCR, DC Excitaiton Systems, Brushless
Voltage
220V, 380V, 400V, 440V, 6300V, 10500V, Ect
Experience
More Than 60 Years Experience
Delivery Time
2~16 Months After Received The Down Payment
Material Available
Stainless Steel Zg0cr13ni4mo, Carbon Steel, Ect
Transport Package
Standard Export Wooden Cases, Seaworthy Packing
Specification
CE / IEC
Trademark
fuchun
Origin
China
Production Capacity
1000

Product Description

Small Francis turbine / Francis turbine for hydro power plant

Small Francis Turbine / Francis Turbine for Hydro Power Plant

Francis turbine
Francis turbine is a kind of turbine suit to water head 20-300meters and with certain suitable flow.
It could be divided into vertical and horizontal arrangement. Francis turbine have the advantage of high efficiency, small size and reliable structure.

Horizontal Francis turbine unit, with horizontal shaft, could be 2 or three supports. Which is normally one stair arrangement. Simple structure, easier operation and maintainence.
Vertical Francis turbine unit, with vertical shaft, metal spiral case or concrete spiral case. With adjustable guide vane, and stay ring etc parts, are suit to runner diameter bigger than 1000mm. Our engineer will select the most suitable Francis turbine for your hydro power project.

Francis runner

Francis runner material could be stainless steel or carbon steel. The upper crown, lower ring, and blades are partial casted, polished, and then welded together. After heat treatment and fine polished, the factory tests including static and dynamic balance test, UT test, and dimension measurement. Our runners are guaranteed 100% all parameters meet the requirement, and related regulation.


Fuchun Industry Development Co., ltd Shenzhen is an experienced manufacture and engineering Company in small scale hydro power equipment ( 50Kw to 50Mw). We play the role of manufacture and EPC contractor andcould supply water to wire equipments and services.
Fuchun has a experienced and professional team to work for site survey, civil work design and power system design. Also there is a strong after sale service to serve at different projects in the world.
We can provide customers with the complete package, from the design and manufacture of the turbine, generator and control equipment through to installation, commissioning and ongoing repair and maintenance.
1. Water Turbine Generator Unit Design & SUPPLY
2. Hydropower equipment supply
3. Feasibility study of hydropower project
4. Manufacture
5. Installation & Supervision
6. Commissioning and Training service
7. Hydro power plant rehabilitant
8. Hydro power plant spares supply
9. Services


Reference List of Some Export Projects
No. Country and Power Station Exported to Technical Parameters Type Qty Date of contract
1 Latin America Rated head:305m
Rated flow:0.385m³/s
Frequency:60Hz
Outgoing line voltage:480V
CJA475-W-80/2×6.5
SFW1000-8/1180
1 2013.06
2 South Asia Type:HL855a
Runner diameter:1750mm
27Mw spare runners  1 2013.06
3 Europe  Rated head:73.8m
Rated flow:0.1325m³/s
Frequency:50Hz
Outgoing line voltage:400V
CJA237-W-55/1×7 1 2013.03
4 Europe Rated head:203m
Rated flow:0.312m³/s
Frequency:50Hz
Outgoing line voltage:400V
CJA237-W-80/1×8.5
SFW500-8/990
1 2013.05
5 South Asia Rated head:88m
Rated flow:1.41m³/s
Frequency:50Hz
Outgoing line voltage:400V
HLA550-WJ-62
SFW1000-6/1180
1 2013.05
6 West Africa Rated head:210m
Rated flow:0.423m³/s
Frequency:50Hz
Outgoing line voltage:400V
CJA237-W-80/1×9.5
SFW700-8/1180
1 2013.05
7  
Latin America
Rated head:925m
Rated flow:0.26m³/s
Frequency:60Hz
Outgoing line voltage:4.16KV
CJC601-W-100/1×5
SFW1980-6/1430
2 2012.12
8
Southeast Asia
Rated head:4m
Rated flow:10m³/s
Frequency:60Hz
Outgoing line voltage:440V
ZD-LH-160
SF320-36/2150
1 2012.12
9
Latin America
Rated head:128m
Rated flow:0.6+0.3m³/s
Frequency:60Hz
Outgoing line voltage:440V
CJA475-W-80/2×9
SFW614-12/1180
CJA475-W-80/2×6.5
SFW302-12/990
2 2012.11
10 Europe Rated head:48.51m
Rated flow:0.351m³/s
Frequency:50Hz
Outgoing line voltage:400V
XJA-W-55B/1x8.5 1 2012.11
11 Europe Rated head:47.48m
Rated flow:0.38m³/s
Frequency:50Hz
Outgoing line voltage:400V
HL110-WJ-42 1 2012.11
12 Europe Rated head:25.44m
Rated flow:0.332m³/s
Frequency:50Hz
Outgoing line voltage:400V
HLD54-WJ-50 1 2012.11
13 Europe  Rated head:35.19m
Rated flow:0.3m³/s
Frequency:50Hz
Outgoing line voltage:400V
HLD54-WJ-50 1 2012.11
14 Europe  Rated head:37.82m
Rated flow:0.291m³/s
Frequency:50Hz
Outgoing line voltage:400V
HLD54-WJ-50 1 2012.11
15 Latin America Rated head:60m
Rated flow:1.24m³/s
Frequency:60Hz
Outgoing line voltage:440V
HLA575c-WJ-56
SFW600-8/990
2 2012.8
16 Europe Rated head:58.1m
Rated flow:0.169m³/s
Frequency:50Hz
Outgoing line voltage:400V
XJA-W-40/1×9
SFW100-8/590
1 2012.04
17 Latin America Rated head:38m
Rated flow:1.64m³/s
Frequency:60Hz
Outgoing line voltage:440V
HL220-WJ-50
SFW470-8/990
1 2012.04
18 Europe Rated head:43m
Rated flow:0.59m³/s
Frequency:50Hz
Outgoing line voltage:400V
HL110-WJ-42
HLD54-WJ-40
2 2012.03
19 South Asia Type:HL855a
Runner diameter:1750mm
27Mw spare runners  3 2011.11
20 Europe Rated head:134m
Rated flow:0.25m³/s
Frequency:50Hz
Outgoing line voltage:400V
CJA475-W-80/2×6.5
SFW250-10/850
2 2011.06
21 Europe Rated head:228m
Rated flow:0.4m³/s
Frequency:50Hz
Outgoing line voltage:400V
CJA475-W-85/1×9.5
SFW715-8/1180
3 2011.05
22 Europe Rated head:61.8m
Rated flow:0.221m³/s
Frequency:50Hz
Outgoing line voltage:400V
XJA-W-42/1×10
SFW100-8/590
1 2011.03
23 Europe  Rated head:379.7m
Rated flow:0.685m³/s
Frequency:50Hz
Outgoing line voltage:10.5KV
CJA475-W-105/2×7.5
SFW2150-8/1730
1 2010.12
24 Europe  Rated head:461.6m
Rated flow:0.786m³/s
Frequency:50Hz
Outgoing line voltage:10.5KV
CJA475-W-115/2×8
SFW3000-8/1730
1 2010.12
25 Europe Rated head:29m
Rated flow:3.2m³/s
Frequency:50Hz
Outgoing line voltage:400V
HLD41-WJ-42
HLD74-WJ-60
2 2010.12
26
Middle Asia
Rated head:36m
Rated flow:1.67m³/s
Frequency:50Hz
Outgoing line voltage:400V
HL295-LJZ-50
SF500--6/850
5 2010.12
27  
South Asia
Rated head:206m
Rated flow:0.89m³/s
Frequency:50Hz
Outgoing line voltage:6.6kV
CJA475-W-100/2×10
SFW1500-10/1430
2 2010.08
28 Southeast Asia Rated head:385m
Rated flow:11.24m³/s
Frequency:50Hz
Outgoing line voltage:13.8kV
(37.5Mw)HL69-LJ-205
SF37500-10/3600
2 2010.02
29  
East Asia
Rated head:206.8m
Rated flow:0.358m³/s
Frequency:50Hz
Outgoing line voltage:400V
CJA237-W-80/1×9
SFW570-8/990
1 2010.04
30
South Asia
Rated head:47.5m
Rated flow:2.62m³/s
Frequency:50Hz
Outgoing line voltage:6.6kV
HLA696-WJ-68
SFW1000-8/1180
3 2010.03
31 Europe Rated head:35m
Rated flow:4.25m³/s
Frequency:50Hz
HLA696-WJ-82
SFW800-12/1430
HLJF2504-WJ-56
SFW400-8/990
3 2010.01
32 Europe Rated head:265m
Rated flow:0.734m³/s
Frequency:50Hz
Outgoing line voltage:6.3kV
CJA475-W-110/2×8.5
SFW1600-10/1730
2 2009.07
33 Europe Rated head:289m
Rated flow:1.775m³/s
Nozzle No.:2
Bucket No.: 20
Runner Outer Diameter: 1600mm
RUNNER DIAMETER: 1300mm
4000KW Pelton runner and shaft spares  3 2009.06
34
Southeast Asia
Rated head:86.2m
Rated flow:22.5m³/s
Frequency:50Hz
Outgoing line voltage:10.5kV
(17Mw) HLA883-LJ-155
SF17000-12/3250
2 2008.01

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2011

Suppliers with verified business licenses

Trading Company
Number of Employees
28
Year of Establishment
1998-07-20