Horizontal or Vertical Francis Turbine for Hydro Power Plant

FOB Price: Get Latest Price
Min. Order: 1 Set
Production Capacity: 500 PCS/Year.
Transport Package: Wooden Case
Payment Terms: L/C, T/T

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: HL
  • Shaft Type: Horizontal / Vertical
  • Trademark: FUCHUN
  • Origin: China
  • Turbine Type: Francis
  • Material: Stainless Steel/Carbon Steel
  • Specification: CE/IEC
Product Description
Horizontal or Vertical Francis Turbine for Hydro Power Plant

Francis turbine

    Francis turbine could be divided into vertical and horizontal arrangement. Francis turbine have the advantage of high efficiency, small size and reliable structure.
 
    Horizontal Francis turbine unit, with horizontal shaft, could be 2 or three supports. Which is normally one stair arrangement. Simple structure, easier operation and maintainence.
Vertical Francis turbine unit, with vertical shaft, metal spiral case or concrete spiral case. With adjustable guide vane, and stay ring etc parts, are suit to runner diameter bigger than 1000mm. Our engineer will select the most suitable Francis turbine for your hydro power project.

    It is mostly suitable for hydro-power stations with medium or high head. The Francis type turbines manufactured by the Fuchun are compact in structure, reasonable in design, convenient in operation and maintenance and excellent in efficiency. They are in both vertical and horizontal shaft arrangement and can be vastly selected by the hydraulic power stations. With many years of our own experience and absorbing advanced technology from domestic and abroad sources, and in meeting ever growing requirements of stations for various hydraulic power resources, the manufacture and design level of Francis turbines made in Fuchun has been raised to new stages.


Francis runner 


    Francis runner material could be stainless steel or carbon steel. The upper crown, lower ring, and blades are partial casted, polished, and then welded together. After heat treatment and fine polished, the factory tests including static and dynamic balance test, UT test, and dimension measurement. Our runners are guaranteed 100% all parameters meet the requirement, and related regulation.  
Horizontal or Vertical Francis Turbine for Hydro Power Plant
Factory Information

       Our factory occupies 560,000 square meters of land, which includes 18 workshops, over 320 sets of heavy and precision producing and testing machinery; scientific research development center in the southern China, and various testing facilities. We have a general technical staff of 380 and 135 senior technical professionals. 
Horizontal or Vertical Francis Turbine for Hydro Power Plant
 
     Our company is an experienced manufacture and engineering Company in small scale hydro power equipment ( 100Kw to 50Mw). We play the role of manufacture and EPC contractor and could supply water to wire equipments and services. As turbine manufacture more than 50 years experience.
   We provide customers with the complete package, from the design and manufacture of the turbine, generator and control equipment through to installation, commissioning and ongoing repair and maintenance.
1.Water Turbine Generator Unit Design & SUPPLY
2.Hydropower equipment supply 
3.Feasibility study of hydropower project
4.Manufacture
5.Installation & Supervision
6.Commissioning and Training service
7. Hydro power plant rehabilitant

8. Hydro power plant spares supply
9.Services

  
Horizontal or Vertical Francis Turbine for Hydro Power Plant

Reference List of Some Export Projects
No. Country and Power Station Exported to Technical Parameters Type Qty Date of contract
1 HPP2
 Guatemala
Rated head:305m
Rated flow:0.385m³/s
Frequency:60Hz
Outgoing line voltage:480V
CJA475-W-80/2×6.5
SFW1000-8/1180
1 2013.06
2  Pakistan  Type:HL855a
Runner diameter:1750mm
27Mw spare runners  1 2013.06
3 UK Rated head:73.8m
Rated flow:0.1325m³/s
Frequency:50Hz
Outgoing line voltage:400V
CJA237-W-55/1×7 1 2013.03
4 turkey Rated head:203m
Rated flow:0.312m³/s
Frequency:50Hz
Outgoing line voltage:400V
CJA237-W-80/1×8.5
SFW500-8/990
1 2013.05
5 Sri Lanka Rated head:88m
Rated flow:1.41m³/s
Frequency:50Hz
Outgoing line voltage:400V
HLA550-WJ-62
SFW1000-6/1180
1 2013.05
6 Congo Rated head:210m
Rated flow:0.423m³/s
Frequency:50Hz
Outgoing line voltage:400V
CJA237-W-80/1×9.5
SFW700-8/1180
1 2013.05
7  
Ecuador
Rated head:925m
Rated flow:0.26m³/s
Frequency:60Hz
Outgoing line voltage:4.16KV
CJC601-W-100/1×5
SFW1980-6/1430
2 2012.12
8
Philippines 
Rated head:4m
Rated flow:10m³/s
Frequency:60Hz
Outgoing line voltage:440V
ZD-LH-160
SF320-36/2150
1 2012.12
9
 Guatemala
Rated head:128m
Rated flow:0.6+0.3m³/s
Frequency:60Hz
Outgoing line voltage:440V
CJA475-W-80/2×9
SFW614-12/1180
CJA475-W-80/2×6.5
SFW302-12/990
2 2012.11
10 UK Rated head:48.51m
Rated flow:0.351m³/s
Frequency:50Hz
Outgoing line voltage:400V
XJA-W-55B/1x8.5 1 2012.11
11  UK Rated head:47.48m
Rated flow:0.38m³/s
Frequency:50Hz
Outgoing line voltage:400V
HL110-WJ-42 1 2012.11
12 UK Rated head:25.44m
Rated flow:0.332m³/s
Frequency:50Hz
Outgoing line voltage:400V
HLD54-WJ-50 1 2012.11
13 UK Rated head:35.19m
Rated flow:0.3m³/s
Frequency:50Hz
Outgoing line voltage:400V
HLD54-WJ-50 1 2012.11
14 UK Rated head:37.82m
Rated flow:0.291m³/s
Frequency:50Hz
Outgoing line voltage:400V
HLD54-WJ-50 1 2012.11
15  HPP1
 Guatemala 
Rated head:60m
Rated flow:1.24m³/s
Frequency:60Hz
Outgoing line voltage:440V
HLA575c-WJ-56
SFW600-8/990
2 2012.8
16 UK Rated head:58.1m
Rated flow:0.169m³/s
Frequency:50Hz
Outgoing line voltage:400V
XJA-W-40/1×9
SFW100-8/590
1 2012.04
17 Ecuador Rated head:38m
Rated flow:1.64m³/s
Frequency:60Hz
Outgoing line voltage:440V
HL220-WJ-50
SFW470-8/990
1 2012.04
18 Italy  Rated head:43m
Rated flow:0.59m³/s
Frequency:50Hz
Outgoing line voltage:400V
HL110-WJ-42
HLD54-WJ-40
2 2012.03
19  Pakistan  Type:HL855a
Runner diameter:1750mm
27Mw spare runners  3 2011.11
20 ITALY Rated head:134m
Rated flow:0.25m³/s
Frequency:50Hz
Outgoing line voltage:400V
CJA475-W-80/2×6.5
SFW250-10/850
2 2011.06
21 Italy Rated head:228m
Rated flow:0.4m³/s
Frequency:50Hz
Outgoing line voltage:400V
CJA475-W-85/1×9.5
SFW715-8/1180
3 2011.05
22  UK Rated head:61.8m
Rated flow:0.221m³/s
Frequency:50Hz
Outgoing line voltage:400V
XJA-W-42/1×10
SFW100-8/590
1 2011.03
23 HPP1
Albania
Rated head:379.7m
Rated flow:0.685m³/s
Frequency:50Hz
Outgoing line voltage:10.5KV
CJA475-W-105/2×7.5
SFW2150-8/1730
1 2010.12
24  HPP2
Albania
Rated head:461.6m
Rated flow:0.786m³/s
Frequency:50Hz
Outgoing line voltage:10.5KV
CJA475-W-115/2×8
SFW3000-8/1730
1 2010.12
25  Italy  Rated head:29m
Rated flow:3.2m³/s
Frequency:50Hz
Outgoing line voltage:400V
HLD41-WJ-42
HLD74-WJ-60
2 2010.12
26
Afghanistan 
Rated head:36m
Rated flow:1.67m³/s
Frequency:50Hz
Outgoing line voltage:400V
HL295-LJZ-50
SF500--6/850
5 2010.12
27  
Pakistan
Rated head:206m
Rated flow:0.89m³/s
Frequency:50Hz
Outgoing line voltage:6.6kV
CJA475-W-100/2×10
SFW1500-10/1430
2 2010.08
28  HPP1
Vietnam
Rated head:385m
Rated flow:11.24m³/s
Frequency:50Hz
Outgoing line voltage:13.8kV
HL69-LJ-205
SF37500-10/3600
2 2010.02
29  
Mozambique
Rated head:206.8m
Rated flow:0.358m³/s
Frequency:50Hz
Outgoing line voltage:400V
CJA237-W-80/1×9
SFW570-8/990
1 2010.04
30
Pakistan 
Rated head:47.5m
Rated flow:2.62m³/s
Frequency:50Hz
Outgoing line voltage:6.6kV
HLA696-WJ-68
SFW1000-8/1180
3 2010.03
31  Italy  Rated head:35m
Rated flow:4.25m³/s
Frequency:50Hz
HLA696-WJ-82
SFW800-12/1430
HLJF2504-WJ-56
SFW400-8/990
3 2010.01
32 Italy  Rated head:265m
Rated flow:0.734m³/s
Frequency:50Hz
Outgoing line voltage:6.3kV
CJA475-W-110/2×8.5
SFW1600-10/1730
2 2009.07
33 Georgia Rated head:289m
Rated flow:1.775m³/s
Nozzle No.:2
Bucket No.: 20
Runner Outer Diameter: 1600mm
RUNNER DIAMETER: 1300mm
4000KW Pelton runner change  3 2009.06
34
Vietnam
Rated head:86.2m
Rated flow:22.5m³/s
Frequency:50Hz
Outgoing line voltage:10.5kV
HLA883-LJ-155
SF17000-12/3250
2 2009.01